Organické látky detegované v heliovém okruhu experimentální výzkumné aparatury k simulaci chlazení jaderného reaktoru při zahájení provozu

Get it

High-temperature He loop is a new experimental device for investigation of structural materials for high-temperature gas-cooled reactors. In the first period of the test operation of the device organic compounds were detected in the loop. At low temperatures ethanol and acetone predominated, at higher temperatures more complex organic compounds were observed. full description

Saved in:

Bibliographic Details

Main Author
Jan Berka
Other Authors
Ivan Víden, 1951-
Václav Kozmík
Document Type
Articles
Physical Description
6 il.
Published in
Chemické listy. -- ISSN 0009-2770. -- Roč. 106, č. 10 (2012), s. 980-987
Subjects
Item Description
2 tabulky, 1 schema, 3 grafy
Bibliography
Literatura na s. 986 (28 zázn.)

Source:

Information about source

Destination Accessibility Link Link source
Web záznam v BMČ Bibliographia medica Čechoslovaca
Web Link Neznámý
Web domovská stránka časopisu - plný text volně přístupný Bibliographia medica Čechoslovaca